Basic Info.
Certification
CE, ISO13485
Product Type
Ivd Semi-Finish Material Uncut Sheet
Delivery Time
7-15 Workdays
Method
Colloidal Gold Rapid Test
Transport Package
Plastic Bag, Sealed Carton
Specification
300*60mm, 300*80mm Customized
Product Description
Product Description
Influenza virus is the representative species of the Orthomyxoviridae family. The typical clinical symptoms of these diseases are acute high fever, general pain, marked fatigue and respiratory symptoms.
Influenza viruses are spread mainly through airborne droplets, contact between a susceptible person and an infected person, or contact with contaminated objects.
The General autumn-winter season is its high incidence period. Influenza A and B viruses mainly caused human influenza.
The rapid diagnosis of Flu is using the immunofluorescence method, ELISA method to detect virus antigen.
We usually take the patient's nasal mucosa or respiratory tract exfoliated epithelial cell smear and see the antigen by immunofluorescence staining with fluorescin-labelled influenza virus immune serum. Or test the antigen in the patient's pharyngeal gargle by ELISA.
Uncut sheet for Rapid Test Kit (Immunochromatographic Assay) is suitable for in vitro qualitative detection of Specific substances in human or animal body fluids, fecal samples, such as proteins, steroids, etc.And it can also be suitable for detecting the content of residual pesticides and other substances in plants or the environment.
Generally speaking,a rapid detection reagent card developed based on side flow chromatography immunoassay has two pre coating lines, namely the "T" test line and the "C" control line on the nitrocellulose membrane. The test line is coated with specific antibodies to capture the target antigen in the sample solution, while the quality control line is coated with other antibodies. Fix colloidal gold particles labeled with monoclonal antibodies against the target antigen onto one end of the test card. When it reaches the testing line, it encounters encapsulated antibodies, forming an antibody antigen gold standard antibody complex. A red band appears in the testing area, and the result is positive. If the target substance is not present in the sample, there will be no red band in the detection area and the result will be negative. The presence of a quality control line (which should be displayed as a red stripe on all samples) indicates that the test card is working properly.
Result Interpretation
Negative result
Only the quality control C line appears and the detection T line does not show color, it indicates that t there is no determinand in the specimen.
Positive Result
Both the quality control C line and the detection T line appear, aThis indicates that the specimen contains detectable amount of determinand.
Invalid Result
No visible colored band appears at control line after performing the test.
Review the test procedure and repeat the test using a new test device.
NOTE:
The intensity of the color in test region (T) may vary depending on the concentration of aimed substances present in the specimen. Therefore, any shade of color in the test region should be considered positive. Besides, the substances level can not be determined by this qualitative test.
Insufficient specimen volume, incorrect operation procedure, or performing expired tests are the most likely reasons for control band failure.
Detailed Photos
Product lists
Uncut Sheet of Rapid test Kit-Colloidal gold |
Chlamydia | C. pneumoniae | H. Pylori | Malaria |
Rotavirus | Adenovirus | Rota/Adeno | Strep A |
Syphilis | HBsAg | HBsAb | HBsAg and HCV |
HBsAg /HCV /HIV /Syphilis | Dengue IgG/IgM | Dengue Ns1 | Dengue IgG/IgM /NS1 |
Chikungunya | Cholera | Typhoid | Tuberculosis |
HIV1+2 | HIV1+2 Ag/Ab | HAV | ToRCH |
HCV | HSV | RSV | TOXO |
Rubella | CMV | Norovirus | Leishmania |
Filariasis | Leptospira | Monkeypox | M.Pneumoniae |
Chagas | Brucella | HPV | nCoV |
Influenza A+B | Influenza A+B/ nCoV | Influenza A+B/nCoV/RSV | FOB |
HCG | LH | IGFBP-1 | fFN |
AMH | AMH/FSH | MxA | cTnI |
25-OH VD | The Customized cut -off and size are available |
Uncut Sheet of Lateral Flow Quantitive Test Kit |
Class | Rapid Test | Sample type | Detection Range |
Cardiac Marker | cTn I | Serum/Plasma/Whole blood | 0.1~40 ng/mL |
NT-proBNP | Serum/Plasma/Whole blood | 100~20000 pg/mL |
CK-MB | Serum/Plasma/Whole blood | 1ng/mL~100ng/mL |
BNP | Plasma/Whole blood | 5pg/mL~5000pg/mL |
cTnT | Serum/Plasma/Whole blood | 30pg/mL~25000pg/mL |
Myo | Serum/Plasma/Whole blood | 5ng/mL~500ng/mL |
cTnl/ Myo/ CK-MB | Serum/Plasma/Whole blood | cTnI: 0.1ng/mL~40ng/mL;Myo: 5ng/mL~500ng/mL;CK-MB: 1ng/mL~100ng/mL |
D-Dimer/ cTnI/ NT-proBNP | Serum/Plasma/Whole blood | Dimer: 0.1mg/L~10mg/L; cTnI: 0.1ng/mL~40ng/mL; NT-proBNP: 100pg/mL~20000pg/mL |
Inflammatory | PCT | Serum/Plasma/Whole blood | 0.1~100 pg/mL |
CRP | Serum/Plasma/Whole blood | 0.5~200mg/L |
SAA | Serum/Plasma/Whole blood | 5~300mg/L |
IL-6 | Serum/Plasma/Whole blood | 5~5000 pg/mL |
PCT/ IL-6 | Serum/Plasma/Whole blood | PCT: 0.1ng/mL~100ng/mL;IL-6:10pg/mL~10000pg/mL |
CRP/ SAA | Serum/Plasma/Whole blood | CRP 0.5mg/L~200mg/L;SAA 5mg/L~300mg/L, |
Glycated hemoglobin | HbA1c | Whole blood | 3~14% |
Tumor | PSA | Serum/Plasma/Whole blood | 2~80 ng/mL |
HCG | HCG | Serum/Plasma/Whole blood | 5~200000mIU/mL |
Anticoagulation | D-Dimer | Plasma/Whole blood | 0.1~10 mg/L |
Endocrine | TSH | Serum/Plasma/Whole blood | 0.1mIU/L ~100.0mIU/L |
T3 | Serum/Plasma/Whole blood | 0.61~9.22 nmol/L |
T4 | Serum/Plasma/Whole blood | 12.87~310 nmol/L |
FT3 | Serum/Plasma/Whole blood | 0.60pmol/L ~45.00pmol/L |
FT4 | Serum/Plasma/Whole blood | 1.00pmol/L ~100.00pmol/L |
AMH | Serum/Plasma/Whole blood | 0.1~16 ng/mL |
PROG | Serum/Plasma | 0.35ng/mL~60ng/mL |
PRL | Serum/Plasma/Whole blood | 1 ng/mL~200ng/mL |
FSH | Serum/Plasma/Whole blood | 1mIU/mL~100 mIU/mL |
LH | Serum/Plasma/Whole blood | 1 ~100 mIU/mL |
TES | Serum/Plasma | 0.2~15 ng/mL |
E2 | Serum/Plasma/Whole blood | 15 pg/mL~3000pg/mL |
Bone | 25-OH-VD | Serum/Plasma/Whole blood | 5.0ng/mL~100.0ng/mL |
The Customized cut -off and size are available |
Company Profile
Certifications
Transportation and Payment
Address:
10th Floor, Building 3, Nam Tai Inno Park, Shenzhen, Guangdong, China
Business Type:
Manufacturer/Factory, Trading Company
Business Range:
Health & Medicine, Instruments & Meters
Management System Certification:
GMP, ISO 13485
Company Introduction:
Shenzhen Sekbio Co., Ltd is a high-tech enterprise specializing in the research, development, production, and manufacturing of biological raw materials, IVD reagents and instruments with a variety of items and competitive price. Our 2000 square meter facility is operated strictly under ISO 13485: 2016 guidelines. Strict quality control, strong R&D team, and good service make our products enjoy a high reputation both in China and abroad. As an innovative diagnostics company with more than 10 years′ Experience, we provides reliable and excellent information through the diagnostic tests with the leading-edge technology you need. Accomplishing the mission of "committed to making diagnostics more accurate" is our goal. We do care about obtaining the trust from our partners and patients. We are dedicated to innovation in the fields of Rapid Test, POCT, In-Vitro Diagnostics, and Medical Consumables. We are committed to provide most reliable medical devices and solutions to people in every corner of the earth.