Quality Guaranteed Uncut Sheet of HIV 1/2/O Tri‐ Line Human Immunodeficiency Virus Rapid Test

Product Details
Customization: Available
Type: IVD Reagent
Certification: CE, ISO13485
Still deciding? Get samples of US$ 5/sheet
Request Sample
Manufacturer/Factory, Trading Company

360° Virtual Tour

Diamond Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

  • Quality Guaranteed Uncut Sheet of HIV 1/2/O Tri‐ Line Human Immunodeficiency Virus Rapid Test
  • Quality Guaranteed Uncut Sheet of HIV 1/2/O Tri‐ Line Human Immunodeficiency Virus Rapid Test
  • Quality Guaranteed Uncut Sheet of HIV 1/2/O Tri‐ Line Human Immunodeficiency Virus Rapid Test
  • Quality Guaranteed Uncut Sheet of HIV 1/2/O Tri‐ Line Human Immunodeficiency Virus Rapid Test
  • Quality Guaranteed Uncut Sheet of HIV 1/2/O Tri‐ Line Human Immunodeficiency Virus Rapid Test
  • Quality Guaranteed Uncut Sheet of HIV 1/2/O Tri‐ Line Human Immunodeficiency Virus Rapid Test
Find Similar Products
  • Overview
  • Product Description
  • Result Interpretation
  • Detailed Photos
  • Product lists
  • Company Profile
  • Certifications
  • Transportation and Payment
Overview

Basic Info.

Model NO.
S13-HIV-2
Warranty
2 Years
Product Type
Ivd Semi-Finish Material Uncut Sheet
Delivery Time
7-15 Workdays
Method
Colloidal Gold Rapid Test
Transport Package
Plastic Bag, Sealed Carton
Specification
300*60mm, 300*80mm Customized
Trademark
Sekbio/OEM
Origin
Shenzhen
HS Code
3002150090
Production Capacity
1000000

Product Description

 

Product Description

Quality Guaranteed Uncut Sheet of HIV 1/2/O Tri‐ Line Human Immunodeficiency Virus Rapid Test
Uncut sheet of   HIV 1/2/OTri‐line Human Immunodeficiency Virus Rapid TestDevice / Strip (Whole Blood/Serum/Plasma) is a qualitative, membrane based immunoassay for the detection of antibodies to HIV‐1,HIV‐2, and SubtypeO in whole blood, serum or plasma. The membrane is pre‐coated withrecombinantHIV antigens in the testlineregions,T1 and T2. The T1 testlineis pre‐coatedwithHIV‐1 and SubtypeO antigenand the T2 testline is pre‐coatedwithHIV‐2 antigen.During testing,the wholeblood, serum or plasma specimen reactswithHIV antigen coated particles in the test strip.The mixture then migrates upward on the membrane chromatographically by capillary actionand reactswith recombinantHIV antigen on the membrane in the testline region.If the specimen contains antibodies to HIV‐1 and/or SubtypeO, or HIV‐2, one colored linewill appear in the testline region; if the specimen contains antibodies to HIV‐1 and/or SubtypeO, and HIV‐2,two colored lineswill appear in the test line region.Bothindicate a positive result. If the specimen does not containHIV‐1, SubtypeO, and/orHIV‐2 antibodies, no colored linewill appear in the testline region indicating a negative result.To serve as a procedural control, a coloredlinewill always appear in the controlline region indicating that proper volume of specimen has been added and membrane wicking has occurred.


 

Result Interpretation

Quality Guaranteed Uncut Sheet of HIV 1/2/O Tri‐ Line Human Immunodeficiency Virus Rapid Test
Negative result
The colored line in the control line region (C) appears.No line appears in test lineregions1 or2 (T1orT2).

Positive Result
HIV1/orO Positive:* The coloredlinein the controlline region(C) appears and a colored line appears in testline region 1 (T1). The resultis positive for
HIV1/orOinfection
HIV2 Positive: * The colored line in the controlline region (C) appears and a colored line appears in test line region 2 (T2).The resultis positive for HIV 2 infection
HIV 1&2 &/or O Positive: * The colored line in the control line region (C) appears and two colored lines should appear in testline regions 1 and 2 (T1 and T2). The color intensities of the lines do not have to match. The result is positiveforHIV1&2&/orO infection.

Invalid Result
No visible colored band appears at control line after performing the test.Review the test procedure and repeat the test using a new test device.

NOTE:
The intensity of the color in test region (T) may vary depending on the concentration of aimed substances present in the specimen. Therefore, any shade of color in the test region should be considered positive. Besides, the substances level can not be determined by this qualitative test.
Insufficient specimen volume, incorrect operation procedure, or performing expired tests are the most likely reasons for control band failure.

 

Detailed Photos

 

Quality Guaranteed Uncut Sheet of HIV 1/2/O Tri‐ Line Human Immunodeficiency Virus Rapid Test
Quality Guaranteed Uncut Sheet of HIV 1/2/O Tri‐ Line Human Immunodeficiency Virus Rapid Test
Quality Guaranteed Uncut Sheet of HIV 1/2/O Tri‐ Line Human Immunodeficiency Virus Rapid Test
Quality Guaranteed Uncut Sheet of HIV 1/2/O Tri‐ Line Human Immunodeficiency Virus Rapid Test

Product lists

Uncut Sheet of Rapid test Kit-Colloidal gold

Chlamydia

C. pneumoniae 

H. Pylori

Malaria

Rotavirus 

Adenovirus

Rota/Adeno 

Strep A

Syphilis 

HBsAg

HBsAb

HBsAg and HCV 

HBsAg /HCV /HIV /Syphilis 

Dengue IgG/IgM 

Dengue Ns1

Dengue IgG/IgM /NS1 

Chikungunya

Cholera 

Typhoid 

Tuberculosis

HIV1+2

HIV1+2 Ag/Ab

HAV

ToRCH

HCV 

HSV  

RSV

TOXO 

Rubella 

CMV

Norovirus

Leishmania 

Filariasis 

Leptospira

Monkeypox

M.Pneumoniae

Chagas 

Brucella

HPV

nCoV

Influenza A+B 

Influenza A+B/ nCoV

Influenza A+B/nCoV/RSV

FOB

HCG LH  IGFBP-1 fFN

AMH

AMH/FSH

MxA

cTnI

25-OH VD The Customized cut -off and size are available
 
Uncut Sheet of Lateral Flow Quantitive Test Kit

Class

Rapid Test

Sample type

Detection Range

Cardiac Marker

cTn I

Serum/Plasma/Whole blood

0.1~40 ng/mL

NT-proBNP

Serum/Plasma/Whole blood

100~20000 pg/mL

CK-MB

Serum/Plasma/Whole blood

1ng/mL~100ng/mL

BNP

Plasma/Whole blood

5pg/mL~5000pg/mL

cTnT

Serum/Plasma/Whole blood

30pg/mL~25000pg/mL

Myo

Serum/Plasma/Whole blood

5ng/mL~500ng/mL

cTnl/ Myo/ CK-MB

Serum/Plasma/Whole blood

cTnI: 0.1ng/mL~40ng/mL;Myo: 5ng/mL~500ng/mL;CK-MB: 1ng/mL~100ng/mL

D-Dimer/ cTnI/ NT-proBNP

Serum/Plasma/Whole blood

Dimer: 0.1mg/L~10mg/L; cTnI: 0.1ng/mL~40ng/mL; NT-proBNP: 100pg/mL~20000pg/mL

Inflammatory

PCT

Serum/Plasma/Whole blood

0.1~100 pg/mL

CRP

Serum/Plasma/Whole blood

0.5~200mg/L

SAA

Serum/Plasma/Whole blood

5~300mg/L

IL-6

Serum/Plasma/Whole blood

5~5000 pg/mL

PCT/ IL-6

Serum/Plasma/Whole blood

PCT: 0.1ng/mL~100ng/mL;IL-6:10pg/mL~10000pg/mL

CRP/ SAA

Serum/Plasma/Whole blood

CRP 0.5mg/L~200mg/L;SAA 5mg/L~300mg/L,

Glycated hemoglobin

HbA1c

Whole blood

3~14%

Tumor

PSA

Serum/Plasma/Whole blood

2~80 ng/mL

HCG

HCG

Serum/Plasma/Whole blood

5~200000mIU/mL

Anticoagulation

D-Dimer

Plasma/Whole blood

0.1~10 mg/L

Endocrine

TSH

Serum/Plasma/Whole blood

0.1mIU/L ~100.0mIU/L

T3

Serum/Plasma/Whole blood

0.61~9.22 nmol/L

T4

Serum/Plasma/Whole blood

12.87~310 nmol/L

FT3

Serum/Plasma/Whole blood

0.60pmol/L ~45.00pmol/L

FT4

Serum/Plasma/Whole blood

1.00pmol/L ~100.00pmol/L

AMH

Serum/Plasma/Whole blood

0.1~16 ng/mL

PROG

Serum/Plasma

0.35ng/mL~60ng/mL

PRL

Serum/Plasma/Whole blood

ng/mL~200ng/mL

FSH

Serum/Plasma/Whole blood

1mIU/mL~100 mIU/mL

LH

Serum/Plasma/Whole blood

1 ~100 mIU/mL

TES

Serum/Plasma

0.2~15  ng/mL

E2

Serum/Plasma/Whole blood

15 pg/mL~3000pg/mL

Bone 

25-OH-VD

Serum/Plasma/Whole blood

5.0ng/mL~100.0ng/mL

The Customized cut -off and size are available

Company Profile


Quality Guaranteed Uncut Sheet of HIV 1/2/O Tri‐ Line Human Immunodeficiency Virus Rapid Test

Certifications


Quality Guaranteed Uncut Sheet of HIV 1/2/O Tri‐ Line Human Immunodeficiency Virus Rapid Test

Transportation and Payment


Quality Guaranteed Uncut Sheet of HIV 1/2/O Tri‐ Line Human Immunodeficiency Virus Rapid Test

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier